Horizontal new brand low temperature liquid CO2 storage tanks

Horizontal new brand low temperature liquid CO2 storage tanks

Horizontal new brand low temperature liquid CO2 storage tanksProduct IntroductionThe physical properties of liquid carbon dioxide and liquid oxygen vary. In general, the storage temperature of the liquid carbon dioxide tank is -20 ℃ and the liquid...

Email: [email protected]

Wechat/Whatsapp: +86 18839759973

Add: NO. 591 WENFENG ROAD, WENFENG DISTRICT, ANYANG, HENAN, CHINA

Horizontal new brand low temperature liquid CO2 storage tanks

Product Introduction

The physical properties of liquid carbon dioxide and liquid oxygen vary. In general, the storage temperature of the liquid carbon dioxide tank is -20 ℃ and the liquid oxygen temperature is -186 ℃. The same is that they are both insulated storage tanks with PU insulation or double layer vacuum insulation. However, the internal material requirements of carbon dioxide storage tanks are not as high as those of oxygen storage tanks. After all, the temperature is not as low as liquid oxygen. The other is design printing. The design pressure of the carbon dioxide tanker is generally 2.0-2.5 Mp and the liquid oxygen tank is generally 0.8-1.6 Mp.

Feature

According to section 6.3.2.1 of GB18442 "Cryogenically insulated pressure vessel", "The active volume should not exceed 95% of the geometric volume, and therefore the fill factor is less than 0.95." Most manufacturers of low temperature pressure vessels nowadays range from 0.9 to 0.95. You can also opt for this method. The lower the fill factor, the larger the gas phase space, which is relatively safe. However, to achieve a fixed active volume, the geometric volume is larger and the material consumption is slightly higher.

Note

When spraying the carbon dioxide tank, the environment should be the most important environment. The temperature of the paint structure in the environment should not exceed 5 degrees and the humidity should not exceed 85%. Outdoor structures are prohibited in rain, snow, fog and strong wind. Construction is not allowed if there is crystallization on the skin surface. It is prohibited to paint films exposed to the sun during the coating and drying process. The surface temperature of the coated parts should not exceed 60 degrees. The construction site should be ventilated and there should be no dust when coating and drying the coating. And other foreign objects fly away.


Send Your Inquiry

We not only provide a good product, but also provide high quality service. If you are interested in our products,
you can contact us in the following ways.

Previous : Double layer buried double wall SF petrol oil gasoline storage tank for oil station

Next : ​Cryogenic Microbulk Tanks: The Future of On-Site Gas Supply

Copyright    2026 ANYANG SAN HUANG DING METAL MATERIALS CO.,LTD All Rights Reserved.